* M83 - Set E codes relative while in Absolute Coordinates (G90) mode
* M84 - Disable steppers until next move, or use S<seconds> to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
* M85 - Set inactivity shutdown timer with parameter Sseconds. To disable set zero (default)
* M84 - Disable steppers until next move, or use S[seconds] to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
* M85 - Set inactivity shutdown timer with parameter S[seconds]. To disable set zero (default)
* M92 - Set axis_steps_per_unit - same syntax as G92
* M104 - Set extruder target temp
* M105 - Read current temp
...
...
@@ -69,36 +69,37 @@
* M128 - EtoP Open (BariCUDA EtoP = electricity to air pressure transducer by jmil)
* M129 - EtoP Closed (BariCUDA EtoP = electricity to air pressure transducer by jmil)
* M140 - Set bed target temp
* M190 - S[xxx] Wait for bed current temp to reach target temp. Waits only when heating Rxxx Wait for bed current temp to reach target temp. Waits when heating and cooling
* M200 Dmillimeters- set filament diameter and set E axis units to cubic millimeters (use S0 to set back to millimeters).
* M190 - S[xxx] Wait for bed current temp to reach target temp. Waits only when heating
* R[xxx] Wait for bed current temp to reach target temp. Waits when heating and cooling
* M200 - D[millimeters]- set filament diameter and set E axis units to cubic millimeters (use S0 to set back to millimeters).
* M201 - Set max acceleration in units/s^2 for print moves (M201 X1000 Y1000)
* M202 - Set max acceleration in units/s^2 for travel moves (M202 X1000 Y1000) Unused in Marlin!!
* M203 - Set maximum feedrate that your machine can sustain (M203 X200 Y200 Z300 E10000) in mm/sec
* M204 - Set default acceleration: S normal moves T filament only moves (M204 S3000 T7000) im mm/sec^2 also sets minimum segment time in ms (B20000) to prevent buffer underruns and M20 minimum feedrate
* M205 - advanced settings: minimum travel speed S=while printing T=travel only, B=minimum segment time X= maximum xy jerk, Z=maximum Z jerk, E=maximum E jerk
* M205 - advanced settings: minimum travel speed S=while printing T=travel only, B=minimum segment time X= maximum xy jerk, Z=maximum Z jerk, E=maximum E jerk
* M206 - set additional homing offset
* M207 - set retract length S[positive mm] F[feedrate mm/min] Z[additional zlift/hop], stays in mm regardless of M200 setting
* M208 - set recover=unretract length S[positive mm surplus to the M207 S*] F[feedrate mm/min]
* M209 - S[1=true/0=false] enable automatic retract detect if the slicer did not support G10/11: every normal extrude-only move will be classified as retract depending on the direction.
* M218 - set hotend offset (in mm): Textruder_number Xoffset_on_X Yoffset_on_Y
* M218 - set hotend offset (in mm): T[extruder_number] X[offset_on_X] Y[offset_on_Y]
* M220 - S[factor in percent] - set speed factor override percentage
* M221 - S[factor in percent] - set extrude factor override percentage
* M240 - Trigger a camera to take a photograph
* M280 - Position an RC Servo Pindex Sangle/microseconds, ommit S to report back current angle
* M300 - Play beep sound S[frequency] Hz P[duration] ms
* M280 - Position an RC Servo P[index] S[angle/microseconds], ommit S to report back current angle
* M300 - Play beep sound S[frequency Hz] P[duration ms]
* M301 - Set PID parameters P I and D
* M302 - Allow cold extrudes
* M303 - PID relay autotune Stemperature sets the target temperature. (default target temperature = 150C)
* M303 - PID relay autotune S[temperature] sets the target temperature. (default target temperature = 150C)
* M304 - Set bed PID parameters P I and D
* M350 - Set microstepping mode.
* M351 - Toggle MS1 MS2 pins directly.
* M400 - Finish all moves
* M401 - Lower z-probe if present
* M402 - Raise z-probe if present
* M404 - N[dia in mm] Enter the nominal filament width (3mm, 1.75mm) or will display nominal filament width without parameters
* M405 - Turn on Filament Sensor extrusion control. Optional D[delay in cm] to set delay in centimeters between sensor and extruder
* M406 - Turn off Filament Sensor extrusion control
* M407 - Displays measured filament diameter
* M404 - N[dia in mm] Enter the nominal filament width (3mm, 1.75mm) or will display nominal filament width without parameters
* M405 - Turn on Filament Sensor extrusion control. Optional D[delay in cm] to set delay in centimeters between sensor and extruder
* M406 - Turn off Filament Sensor extrusion control
* M407 - Displays measured filament diameter
* M500 - stores paramters in EEPROM
* M501 - reads parameters from EEPROM (if you need reset them after you changed them temporarily).
* M502 - reverts to the default "factory settings". You still need to store them in EEPROM afterwards if you want to.
...
...
@@ -109,7 +110,5 @@
* M666 - Set z probe offset or Endstop and delta geometry adjustment. M666 L for list command
* M907 - Set digital trimpot motor current using axis codes.