* Support for a current sensor (Hall effect sensor like ACS712) for measure the power consumption
* Since it's more simple to deal with, we measure the DC current and we assume that POWER_VOLTAGE that comes from your power supply it's almost stable.
* You have to change the SENSITIVITY with the one that you can find in the datasheet. (in case of ACS712: set to .100 for 20A version or set .066 for 30A version)
* With this module we measure the Printer power consumption ignoring the Power Supply power consumption, so we consider the EFFICIENCY of our supply to be 100% so without
* any power dispersion. If you want to approximately add the supply consumption you can decrease the EFFICIENCY to a value less than 100. Eg: 85 is a good value.
* You can find a better value measuring the AC current with a good multimeter and moltiple it with the mains voltage.
#define POWER_VOLTAGE 12.00 //(V) The power supply OUT voltage
#define POWER_ZERO 2.5 //(V) The /\V coming out from the sensor when no current flow.
#define POWER_SENSITIVITY 0.066 //(V/A) How much increase V for 1A of increase
#define POWER_EFFICIENCY 100.0 //(%) The power efficency of the power supply
//When using an LCD, uncomment the line below to display the Power consumption sensor data on the last line instead of status. Status will appear for 5 sec.