Stefy Lanza (nextime / spora ) authored
Measured on a rented A40 under 128 pages in flight. The engine stopped answering. _ensure_service_once treated any service that failed a 3 s health probe as gone: it dropped it from the table, without stopping the process, and launched another. A second caller during a start did the same, so two EngineCores came up one second apart. For twenty minutes vLLM was relaunched every few seconds and killed with -9 mid-start. This is also the earlier "10.22 of 47 GiB free" crash. - A service records "starting" until it is ready. Another caller waits for it (_StillStarting -> _wait_for_start) instead of launching a duplicate. - A live process that misses the probe gets a second 15 s probe. If that fails too it is BUSY and is handed out, not replaced. - A dead one is stopped properly before it is replaced. - The OCR gateway's /health no longer runs placement.any_candidate (which can start vLLM) on the event loop. Every surya engine probes it, and it froze a pod for up to 408 s. The no-blocking-calls guard now covers placement.any_candidate and placement.candidates, and fails on the old code. - RunPod 429s are honoured: retryAfter is in seconds (observed 11,871, about 3.3 h), and no GraphQL call is made until it passes (capped at 6 h). Co-Authored-By:
Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01KnfkxBpcZ1v6ypRFFyhrVM
ed4e2c2a