// G10 - retract filament according to settings of M207
// G11 - retract recover filament according to settings of M208
// G28 - Home all Axis
// G29 - Detailed Z-Probe, probes the bed at 3 or more points. Will fail if you haven't homed yet.
// G30 - Single Z Probe, probes bed at current XY location. - Bed Probe and Delta geometry Autocalibration
// G31 - Dock sled (Z_PROBE_SLED only)
// G32 - Undock sled (Z_PROBE_SLED only)
// G60 - Memory actual position
// G61 - Move X Y Z to position in memory
// G90 - Use Absolute Coordinates
// G91 - Use Relative Coordinates
// G92 - Set current position to coordinates given
// M Codes
// M0 - Unconditional stop - Wait for user to press a button on the LCD (Only if ULTRA_LCD is enabled)
// M1 - Same as M0
// M03 - Put S<value> in laser beam control
// M04 - Turn on laser beam
// M05 - Turn off laser beam
// M17 - Enable/Power all stepper motors
// M18 - Disable all stepper motors; same as M84
// M20 - List SD card
// M21 - Init SD card
// M22 - Release SD card
// M23 - Select SD file (M23 filename.g)
// M24 - Start/resume SD print
// M25 - Pause SD print
// M26 - Set SD position in bytes (M26 S12345)
// M27 - Report SD print status
// M28 - Start SD write (M28 filename.g)
// M29 - Stop SD write
// M30 - Delete file from SD (M30 filename.g)
// M31 - Output time since last M109 or SD card start to serial
// M32 - Select file and start SD print (Can be used _while_ printing from SD card files):
// syntax "M32 /path/filename#", or "M32 S<startpos bytes> !filename#"
// Call gcode file : "M32 P !filename#" and return to caller file after finishing (similar to #include).
// The '#' is necessary when calling from within sd files, as it stops buffer prereading
// M42 - Change pin status via gcode Use M42 Px Sy to set pin x to value y, when omitting Px the onboard led will be used.
// M49 - Z probe repetability test
// M80 - Turn on Power Supply
// M81 - Turn off Power Supply
// M82 - Set E codes absolute (default)
// M83 - Set E codes relative while in Absolute Coordinates (G90) mode
// M84 - Disable steppers until next move,
// or use S<seconds> to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
// M85 - Set inactivity shutdown timer with parameter S<seconds>. To disable set zero (default)
// M92 - Set axis_steps_per_unit - same syntax as G92
// M104 - Set extruder target temp
// M105 - Read current temp
// M106 - Fan on
// M107 - Fan off
// M109 - Sxxx Wait for extruder current temp to reach target temp. Waits only when heating
// Rxxx Wait for extruder current temp to reach target temp. Waits when heating and cooling
// IF AUTOTEMP is enabled, S<mintemp> B<maxtemp> F<factor>. Exit autotemp by any M109 without F
// M111 - Debug mode
// M112 - Emergency stop
// M114 - Output current position to serial port
// M115 - Capabilities string
// M117 - display message
// M119 - Output Endstop status to serial port
// M126 - Solenoid Air Valve Open (BariCUDA support by jmil)
// M127 - Solenoid Air Valve Closed (BariCUDA vent to atmospheric pressure by jmil)
// M128 - EtoP Open (BariCUDA EtoP = electricity to air pressure transducer by jmil)
// M129 - EtoP Closed (BariCUDA EtoP = electricity to air pressure transducer by jmil)
// M140 - Set bed target temp
// M150 - Set BlinkM Color Output R: Red<0-255> U(!): Green<0-255> B: Blue<0-255> over i2c, G for green does not work.
// M190 - Sxxx Wait for bed current temp to reach target temp. Waits only when heating
// Rxxx Wait for bed current temp to reach target temp. Waits when heating and cooling
// M200 D<millimeters>- set filament diameter and set E axis units to cubic millimeters (use S0 to set back to millimeters).
// M201 - Set max acceleration in units/s^2 for print moves (M201 X1000 Y1000)
// M203 - Set maximum feedrate that your machine can sustain (M203 X200 Y200 Z300 E10000) in mm/sec
// M204 - Set default acceleration: S normal moves T filament only moves (M204 S3000 T7000) in mm/sec^2 also sets minimum segment time in ms (B20000) to prevent buffer under-runs and M20 minimum feedrate
// M205 - advanced settings: minimum travel speed S=while printing T=travel only, B=minimum segment time X= maximum xy jerk, Z=maximum Z jerk, E=maximum E jerk
// M206 - set additional homing offset
// M207 - set retract length S[positive mm] F[feedrate mm/min] Z[additional zlift/hop], stays in mm regardless of M200 setting
// M208 - set recover=unretract length S[positive mm surplus to the M207 S*] F[feedrate mm/sec]
// M209 - S<1=true/0=false> enable automatic retract detect if the slicer did not support G10/11: every normal extrude-only move will be classified as retract depending on the direction.
// M218 - set hotend offset (in mm): T<extruder_number> X<offset_on_X> Y<offset_on_Y>
// M220 S<factor in percent>- set speed factor override percentage
// M221 S<factor in percent>- set extrude factor override percentage
// M226 P<pin number> S<pin state>- Wait until the specified pin reaches the state required
// M240 - Trigger a camera to take a photograph
// M250 - Set LCD contrast C<contrast value> (value 0..63)
// M280 - set servo position absolute. P: servo index, S: angle or microseconds
// M300 - Play beep sound S<frequency Hz> P<duration ms>
// M301 - Set PID parameters P I and D
// M302 - Allow cold extrudes, or set the minimum extrude S<temperature>.
// M303 - PID relay autotune S<temperature> sets the target temperature. (default target temperature = 150C)
// M304 - Set bed PID parameters P I and D
// M400 - Finish all moves
// M401 - Lower z-probe if present
// M402 - Raise z-probe if present
// M404 - N<dia in mm> Enter the nominal filament width (3mm, 1.75mm ) or will display nominal filament width without parameters
// M405 - Turn on Filament Sensor extrusion control. Optional D<delay in cm> to set delay in centimeters between sensor and extruder
// M406 - Turn off Filament Sensor extrusion control
// M407 - Displays measured filament diameter
// M500 - Store parameters in EEPROM
// M501 - Read parameters from EEPROM (if you need reset them after you changed them temporarily).
// M502 - Revert to the default "factory settings". You still need to store them in EEPROM afterwards if you want to.
// M503 - Print the current settings (from memory not from EEPROM). Use S0 to leave off headings.
// M540 - Use S[0|1] to enable or disable the stop SD card print on endstop hit (requires ABORT_ON_ENDSTOP_HIT_FEATURE_ENABLED)
// M600 - Pause for filament change X[pos] Y[pos] Z[relative lift] E[initial retract] L[later retract distance for removal]
// M605 - Set dual x-carriage movement mode: S<mode> [ X<duplication x-offset> R<duplication temp offset> ]
// M666 - Set z probe offset or Endstop and delta geometry adjustment
// M907 - Set digital trimpot motor current using axis codes.
// M908 - Control digital trimpot directly.
// M350 - Set microstepping mode.
// M351 - Toggle MS1 MS2 pins directly.
// ************ SCARA Specific - This can change to suit future G-code regulations
G10 - retract filament according to settings of M207
G11 - retract recover filament according to settings of M208
G28 - Home all Axis
G29 - Detailed Z-Probe, probes the bed at 3 or more points. Will fail if you haven't homed yet.
G30 - Single Z Probe, probes bed at current XY location. - Bed Probe and Delta geometry Autocalibration
G31 - Dock sled (Z_PROBE_SLED only)
G32 - Undock sled (Z_PROBE_SLED only)
G60 - Memory actual position
G61 - Move X Y Z to position in memory
G90 - Use Absolute Coordinates
G91 - Use Relative Coordinates
G92 - Set current position to coordinates given
M Codes
M0 - Unconditional stop - Wait for user to press a button on the LCD (Only if ULTRA_LCD is enabled)
M1 - Same as M0
M03 - Put S<value> in laser beam control
M04 - Turn on laser beam
M05 - Turn off laser beam
M17 - Enable/Power all stepper motors
M18 - Disable all stepper motors; same as M84
M20 - List SD card
M21 - Init SD card
M22 - Release SD card
M23 - Select SD file (M23 filename.g)
M24 - Start/resume SD print
M25 - Pause SD print
M26 - Set SD position in bytes (M26 S12345)
M27 - Report SD print status
M28 - Start SD write (M28 filename.g)
M29 - Stop SD write
M30 - Delete file from SD (M30 filename.g)
M31 - Output time since last M109 or SD card start to serial
M32 - Select file and start SD print (Can be used _while_ printing from SD card files):
syntax "M32 /path/filename#", or "M32 S<startpos bytes> !filename#"
Call gcode file : "M32 P !filename#" and return to caller file after finishing (similar to #include).
The '#' is necessary when calling from within sd files, as it stops buffer prereading
M42 - Change pin status via gcode Use M42 Px Sy to set pin x to value y, when omitting Px the onboard led will be used.
M49 - Z probe repetability test
M80 - Turn on Power Supply
M81 - Turn off Power Supply
M82 - Set E codes absolute (default)
M83 - Set E codes relative while in Absolute Coordinates (G90) mode
M84 - Disable steppers until next move,
or use S<seconds> to specify an inactivity timeout, after which the steppers will be disabled. S0 to disable the timeout.
M85 - Set inactivity shutdown timer with parameter S<seconds>. To disable set zero (default)
M92 - Set axis_steps_per_unit - same syntax as G92
M104 - Set extruder target temp
M105 - Read current temp
M106 - Fan on
M107 - Fan off
M109 - Sxxx Wait for extruder current temp to reach target temp. Waits only when heating
Rxxx Wait for extruder current temp to reach target temp. Waits when heating and cooling
IF AUTOTEMP is enabled, S<mintemp> B<maxtemp> F<factor>. Exit autotemp by any M109 without F
M111 - Debug mode
M112 - Emergency stop
M114 - Output current position to serial port
M115 - Capabilities string
M117 - display message
M119 - Output Endstop status to serial port
M126 - Solenoid Air Valve Open (BariCUDA support by jmil)
M127 - Solenoid Air Valve Closed (BariCUDA vent to atmospheric pressure by jmil)
M128 - EtoP Open (BariCUDA EtoP = electricity to air pressure transducer by jmil)
M129 - EtoP Closed (BariCUDA EtoP = electricity to air pressure transducer by jmil)
M140 - Set bed target temp
M150 - Set BlinkM Color Output R: Red<0-255> U(!): Green<0-255> B: Blue<0-255> over i2c, G for green does not work.
M190 - Sxxx Wait for bed current temp to reach target temp. Waits only when heating
Rxxx Wait for bed current temp to reach target temp. Waits when heating and cooling
M200 D<millimeters>- set filament diameter and set E axis units to cubic millimeters (use S0 to set back to millimeters).
M201 - Set max acceleration in units/s^2 for print moves (M201 X1000 Y1000)
M203 - Set maximum feedrate that your machine can sustain (M203 X200 Y200 Z300 E10000) in mm/sec
M204 - Set default acceleration: S normal moves T filament only moves (M204 S3000 T7000) in mm/sec^2 also sets minimum segment time in ms (B20000) to prevent buffer under-runs and M20 minimum feedrate
M205 - advanced settings: minimum travel speed S=while printing T=travel only, B=minimum segment time X= maximum xy jerk, Z=maximum Z jerk, E=maximum E jerk
M206 - set additional homing offset
M207 - set retract length S[positive mm] F[feedrate mm/min] Z[additional zlift/hop], stays in mm regardless of M200 setting
M208 - set recover=unretract length S[positive mm surplus to the M207 S*] F[feedrate mm/sec]
M209 - S<1=true/0=false> enable automatic retract detect if the slicer did not support G10/11: every normal extrude-only move will be classified as retract depending on the direction.
M218 - set hotend offset (in mm): T<extruder_number> X<offset_on_X> Y<offset_on_Y>
M220 S<factor in percent>- set speed factor override percentage
M221 S<factor in percent>- set extrude factor override percentage
M226 P<pin number> S<pin state>- Wait until the specified pin reaches the state required
M240 - Trigger a camera to take a photograph
M250 - Set LCD contrast C<contrast value> (value 0..63)
M280 - set servo position absolute. P: servo index, S: angle or microseconds
M300 - Play beep sound S<frequency Hz> P<duration ms>
M301 - Set PID parameters P I and D
M302 - Allow cold extrudes, or set the minimum extrude S<temperature>.
M303 - PID relay autotune S<temperature> sets the target temperature. (default target temperature = 150C)
M304 - Set bed PID parameters P I and D
M400 - Finish all moves
M401 - Lower z-probe if present
M402 - Raise z-probe if present
M404 - N<dia in mm> Enter the nominal filament width (3mm, 1.75mm ) or will display nominal filament width without parameters
M405 - Turn on Filament Sensor extrusion control. Optional D<delay in cm> to set delay in centimeters between sensor and extruder
M406 - Turn off Filament Sensor extrusion control
M407 - Displays measured filament diameter
M500 - Store parameters in EEPROM
M501 - Read parameters from EEPROM (if you need reset them after you changed them temporarily).
M502 - Revert to the default "factory settings". You still need to store them in EEPROM afterwards if you want to.
M503 - Print the current settings (from memory not from EEPROM). Use S0 to leave off headings.
M540 - Use S[0|1] to enable or disable the stop SD card print on endstop hit (requires ABORT_ON_ENDSTOP_HIT_FEATURE_ENABLED)
M600 - Pause for filament change X[pos] Y[pos] Z[relative lift] E[initial retract] L[later retract distance for removal]
M605 - Set dual x-carriage movement mode: S<mode> [ X<duplication x-offset> R<duplication temp offset> ]
M666 - Set z probe offset or Endstop and delta geometry adjustment
M907 - Set digital trimpot motor current using axis codes.
M908 - Control digital trimpot directly.
M350 - Set microstepping mode.
M351 - Toggle MS1 MS2 pins directly.
************ SCARA Specific - This can change to suit future G-code regulations