Commit 5788c2e7 authored by Franco (nextime) Lanza's avatar Franco (nextime) Lanza

Merge branch 'master' into k40_noflow_nocooler

parents 691fbcfa bcea222f
Pipeline #65 skipped
......@@ -73,7 +73,7 @@
#define TEMP_SENSOR_2 0
#define TEMP_SENSOR_3 0
#define TEMP_SENSOR_BED 0
#define TEMP_SENSOR_CHAMBER 0 // NOT USED FOR NOW!!!
#define TEMP_SENSOR_CHAMBER 0
#define TEMP_SENSOR_COOLER 0
//These 2 defines help to calibrate the AD595 sensor in case you get wrong temperature measurements.
......
......@@ -3008,7 +3008,7 @@ inline void wait_heater(bool no_wait_for_cooling = true) {
now = millis();
if (ELAPSED(now, next_temp_ms)) { //Print temp & remaining time every 1s while waiting
next_temp_ms = now + 1000UL;
#if HAS(TEMP_HOTEND) || HAS(TEMP_BED)
#if HAS(TEMP_0) || HAS(TEMP_BED) || ENABLED(HEATER_0_USES_MAX6675)
print_heaterstates();
#endif
#if TEMP_RESIDENCY_TIME > 0
......@@ -3083,7 +3083,7 @@ inline void wait_bed(bool no_wait_for_cooling = true) {
now = millis();
if (ELAPSED(now, next_temp_ms)) { //Print Temp Reading every 1 second while heating up.
next_temp_ms = now + 1000UL;
#if HAS(TEMP_0) || HAS(TEMP_BED)
#if HAS(TEMP_0) || HAS(TEMP_BED) || ENABLED(HEATER_0_USES_MAX6675)
print_heaterstates();
#endif
#if TEMP_BED_RESIDENCY_TIME > 0
......
Markdown is supported
0% or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment