<?xml version="1.0" encoding="utf-8"?> <!-- EVERSPRING AN158 ON/OFF MODULE --> <!-- Information from http://www.pepper1.net/zwavedb/device/54 --> <Product xmlns='http://code.google.com/p/open-zwave/'> <!-- Configuration Parameters --> <CommandClass id="112"> <Value type="short" index="1" genre="config" label="True Period" units="100ms" min="0" max="120" value="10"> <Help> This is the time the switching status needs to remain unchanged after a change to cause the device to send out a status message. 0 is Disabled. </Help> </Value> <Value type="byte" index="2" genre="config" label="Send Out Basic Command" units="" min="0" max="1" value="0"> <Help> Enable or Disable Send Basic Command to Group 2 when the local button press changes the switching state. </Help> </Value> <Value type="short" index="3" genre="config" label="Meter Report Period" units="10s" min="0" max="3240" value="3"> <Help> The device will report its meter value within the interval set. Set to 0 will disable the autoreporting function. </Help> </Value> </CommandClass> <!-- Association Groups --> <CommandClass id="133"> <Associations num_groups="2"> <Group index="1" max_associations="1" label="Reports" auto="true" /> <Group index="2" max_associations="4" label="Basic" auto="true" /> </Associations> </CommandClass> </Product>