<?xml version="1.0" encoding="utf-8"?> <Product xmlns='http://code.google.com/p/open-zwave/'> <!-- Configuration Parameters --> <CommandClass id="112"> <Value type="byte" index="1" genre="config" label="Basic Set Level" units="%" min="0" max="99" value="99"> <Help> Defines the level in the Basic Set event sent to group 2 when the sensor is triggered. Default is 99 (full brightness for a Z-Wave dimmer). 0 disables. </Help> </Value> <Value type="short" index="2" genre="config" label="Lux On Trigger" units="LUX" min="0" max="1000" value="300"> <Help> Lux level to trigger when a ON command is sent out. 0 will clear the value. </Help> </Value> <Value type="short" index="3" genre="config" label="Lux Off Trigger" units="LUX" min="0" max="1000" value="500"> <Help> Lux level to trigger when an OFF command is sent out. 0 will clear the value. </Help> </Value> <Value type="short" index="4" genre="config" label="Lux Timer Off Trigger" units="minutes" min="1" max="480" value="240"> <Help> Set Lux timer trigger to send an OFF command. 0 will clear the value. </Help> </Value> <Value type="short" index="5" genre="config" label="Auto Report Time" units="minutes" min="0" max="1439" value="0"> <Help> Sets the auto report time interval. 0 disables. </Help> </Value> <Value type="short" index="6" genre="config" label="Auto Report Lux" units="LUX" min="30" max="1000" value="0"> <Help> Sets the auto report Lux interval. 0 disabled. </Help> </Value> </CommandClass> <!-- COMMAND_CLASS_ALARM doesn't respond --> <CommandClass id="113" getsupported="false" /> <!-- COMMAND_CLASS_ASSOCIATION. Groups --> <CommandClass id="133"> <Associations num_groups="2"> <Group index="1" max_associations="1" label="Reports" auto="true" /> <Group index="2" max_associations="3" label="Basic" auto="true" /> </Associations> </CommandClass> </Product>